Detergent Pump
Part Number
600 30094
Function
When fitted the pump automatically injects detergent into wash tank during filling
of the machine and at the start of each wash cycle.
Description
Fixed Flow Peristaltic Pump PG1.5
Voltage: 230 V 50Hz
Pressure: 0.1 Bar
Flow rate: 1.5 L/h (0.42 ml/sec)
Max suction height: 1.5 M
Diagram
Replacement
Peristaltic pumps provide reliable and accurate detergent dosing. However over
time the squeeze tube in the pump will flatten and become ineffective, and/or split
and leak. We therefore recommend quarterly inspection of the squeeze tube and
replacement every six months in high use situations, particularly when chlorinated
detergents are used.
Adjustment
Standard machine controls operate the detergent pump continuously during filling
of the wash tank. At specified water supply pressures the fill flow is about 12l/min.
The detergent pump dispenses at a rate of 25 ml/min, i.e. the pump is dispensing
2 ml. of detergent per litre of wash water during filling.
The detergent pump is also set to operate during the wash cycle. Factory timer
settings in seconds of pump operation per wash are: XG – 10 sec,
GLV/UD/XP/XU – 15 sec, AL/AL8/PW1/TW – 20 sec, PW2/PW3 – 30 sec.
These settings will deliver about 2 ml of detergent per litre of rinse water
consumed. If the recommended concentration of your detergent is different from
2 ml/litre then the dosing time should be adjusted – refer Timer page in the
Service Manual for instructions. The dosing time T = 2.4 V x C, where V is the
volume of water consumed by the machine per cycle – refer Installation
instructions, and C is the required concentration of your detergent. For example, if
water consumption per cycle is 3 litres and recommended concentration is
3 ml/litre then the dosing time should be adjusted to 22 seconds.
On glasswashers where cold final rinse is used longer injection times are required
to compensate for the dilution of wash water by the cold rinse.